Bibliography - Laboratory Animal Infusion

Adams, MR, Kaplan, JR, Manuck, SB, Uberseder, B, and Larkin, KT. Persistent Sympathetic Nervous System Arousal Associated with Tethering in Cynomolgus Macaques. Laboratory Animal Science 1988; Vol 38, No. 3; 279-281

 

Appelgren, P. Surface heparinization of central venous catheters reduces microbial colonization in vitro and in vivo: Results from a prospective, randomized trial. Critical Care Medicine 1996; Vol 24, No. 9; 1482-1489

 

Bacher, JD, Balis, FM, McCully, CL, and Godwin, KS. Cerebral Subarachnoid Sampling of Cerebrospinal Fluid in the Rhesus Monkey. Laboratory Animal Science; Vol 44. No 2. April 1994; 148-152

 

Bailie, MB, Wixson, SK, and Landi, MS. Vascular-Access-Port Implantation for Serial Blood Sampling in Conscious Swine. Laboratory Animal Science; Vol 36. No 4. August 1986; 431-433

 

Begovac, PC, Thomson, RC, Fisher, JL, Hughson, A, and Gallhagen, A. Improvements in GORE-TEX ® Vascular Graft Performance by Carmeda ® BioActive Surface Heparin Immobilization. Eur J Vasc Endovasc Surg; 25, 2003, 432-437.

 

Chuang, MA, Orvieto, MA, Laven, BA, Gerber, GS, Wardrip, C, Ritch, C, Shalhav, A. Comparison of External Catheters with Subcutaneious Vascular Access Ports for Chronic Vascular Access in a Porcine Model. Contemporary Topics. 44(2) March 2005:pp24-27

 

Fitzgerald, AL, Dillon, LM, Altrogge, DM, Bleavins, MR, Breider, MA. Use of Subcutaneous Vascular Access Port in Common Marmosets (Callithrix jacchus). Contemporary Topics. May 1996. Vol. 35. No.

 

Foley, PL, Barthel, CH, Brausa, HR. Effect of Covalently Bound Heparin Coating on Patency and Bicompatibility of Long-term Indwelling Catheters in Rat Jugular Vein. Comparative Medicine; 2002; Vol 52, No 3; 243-248

 

Fraschini, G. Urokinsase Prophylaxis of Central Venous Ports Reduces Infections and Thrombotic Complications. NAVAN Fifth Annual Conference Syllabsu Abstract; September, 1991; p.33.

 

Garner, D. and Laks, MM. New implanted chronic catheter device for determining blood pressure and cardiac output in conscious dog The American Physiological Society, Special Communications, 1985, 0363-6135

 

Garner, D, McGivern, R, Jagels, G, and Laks, MM. A New Method for Direct Measurement of Systolic and Diastolic Pressures in Concscious Rats Using Vascular-Access-Ports. Laboratory Animal Science; April 1988; Vol 38. No 2.

 

Gilberto, DB, AH. Zeloi, PJ Szczerba, JR Gehret, et al. An Alternative Method of Chronic Cerebrospinal Fluid Collection via the Cisterna Magna in Conscious Rhesus Monkeys. Contemporary Topics, July 2003; Vol 42. No. 4, pg 53.

 

Henderson, KK, EA Mokelke, JR Turk, RS Rector, MH Laughlin, MS Sturek. Maintaining Patency and Asepsis of Vascular Access Ports in Yucatan Miniature Swine. Contemporary Topics, Nov 2003; Vol 42, No. 6.

 

Jacobson, AD, RA Rockar, KK Sadanaga, RJ Scalese. Vascular Access Ports: Research Tool, Clinical Applications and Specific Examples. Proceedings IVECCS VI; San Antonio TX 1998, pg 541.

 

Jacobson, A. Equipment for Continuous Intravenous Infusion. Preclinical, Feb 6, 2000; pg 299.

 

Jacobson, A. Continuous Infusion and Chronic Catheter Access in Laboratory Animals. Lab Animal, July/Aug 1998; Vol 27, No. 7, pg 37-46.

 

Kunta, JR, BA Perry, JP Sutyak, PJ Sinko. Development of a Novel Intestinal and Vascular Access Port (IVAP) Rabbit Model to Study Regiospecific Oral Absorption Pharmacokinetics. Comparative Medicine, Aug 2001; Vol 51, No 4, pg 349-356.

 

Kwei, GY, JR Gehret, LB Novak, MD Drag, T Goodwin. Chronic Catheterization of the Intestines and Portal Vein for Absorption experimentation in Beagle Dogs. Laboratory Animal Science, Dec 1995. Vol 45, No 6, pg 683-685.

 

Landi, M, J Schantz, E Jenkins, C. Warnick & J Kissinger. A Survey of Vascular Access Port Infection in Cynomolgus Monkeys (Macaca fascicularis). Scand. J. Lab. Anim. Sci. 1996. Vol 23, No 1, pg 441.

 

Mann, WA, MS Landi, E Horner, P Woodward, S Campbell and LB Kinter. A Simple Procedure for Direct Blood Pressure Measurements in Conscious Dogs. Laboratory Animal Science Feb 1987. Vol 37, No 1, pg 105-108.

 

Mendenhall, HV, TSI Mason. Chronic Catheterization of the Lateral Ventricle in Cynomolgus Monkeys. SOT 1996 Annual Meeting. No. 1318.

 

Meunier, LD, JT Kissinger, J Marcello, AJ Nichols and PL Smith. A Chronic Access Port Model for Direct Delivery of Drugs into the Intestine of Conscious Dogs. Laboratory Animal Science, Oct 1993; Vol 43, No 5, pg 466-470.

 

Morton, DB, M Jennings, A Buckwell, R. Ewbank, C. Godfrey, et al. Refining Procedures for the Administration of Substances. Laboratory Animals Ltd. Laboratory Animals (2001) 35, pg 1-4.

 

Nolan, TE, HJ Klein. Methods in Vascular Infusion Biotechnology in Research with Rodents. ILAR Journal 2002; Vol 43, No 3, pg 175-179.

 

Nolan, TE, M Loughnane, A Jacobson. Tethered Infusion and Withdrawal in Laboratory Animals. Lab Animal News, Sept/Oct 2004.

Perry-Clark, LM, LD Meunier. Vascular Access Ports for Chronic Serial Infusion and Blood Sampling in New Zealand White Rabbits. Laboratory Animal Science, Oct 1991; Vol 41, No 5, pg 495-497.

 

Raad, II, GP Bodey, Infectious Complications of Indwelling Vascular Catheters. CID Aug 1992; Vol 15, pg 197-208.

 

Rassnick, KM, WJ Gould III, JA Flanders. Use of a Vascular Access System for Administration of Chemotherapeutic Agents to a Ferret with Lymphoma. J of the American Veterinary Medical Association Feb 15, 1995; Vol 206, No 4, pg500-504.

 

Remedios, AM, T Duke. Chronic Epidural Implantation of Vascular Access Catheters in the Cat Lumbosacrum. Laboratory Animal Science June 1993; Vol 43, No 3, pg262-264.

 

Roache, RF, EL Jenkins, VR Vaden, JT Kissinger, RW Coatney. Long Term Portal Vein and Intestinal Access Port Outcomes in the Cynololgus Monkey (Macaca Fascicularis). Academy of Surgical Res. 20 th Annual Scientific Session, Minneapolis, MN; Oct 2004.

 

Rockar, RA, KK Sadanaga, DE Burkett, JG Mitroka, RA Bonner, MJ Weinstein. J. of Investigative Surgery 1995; Vol 8, pg85-94.

 

Swindle, MM, T Nolan, A Jacobson, P Wolf, MJ Dalton, AC Smith. Vascular Access Port (VAP) Usage in Large Animal Species. Contemporary Topics American Association for Laboratory Animal Science May15-17 2005; Vol 44, No 3, pg7-15.

 

Tissot, MC, HB Seim III, A Tucker. Catheterization of the Subarachnoid Space in Rabbits Using a Vascular Access Port.J. of Investigative Surgery 1995; Vol.8 , pg 371-379.

 

Wachtman, LM, MD Browning, D Bedja, S Pin, KL Gabrielson. Validation of the Use of Long-term Indwelling Jugular Catheters in a Rat Model of Cardiotoxicity. Journal of the American Association for Laboratory Animal Science Sep 2006; Vol 45, No 5, pp55-64.

 

Webb, AI, JM Bliss, LH Herbst. Use of Vascular Access Ports in the Cat. Laboratory Animal Science Feb 1995; Vol 45, No1, pg110-114.